T.I.C. Engineering
T.I.C.’s Engineering personnel have decades of experience in
control systems.
T.I.C. has drafters with years of both field and computer
experience which enables us to expedite customer requested
changes on a project.
|
|
|
 |
|
Pneumatic/Hydraulic Control Panel
Total Hydraulic Operated Control Panel
|
|
|
 |
Optional Design:
|
 |
Pneumatic Wing and Master Valves and a Hydraulic Operated Downhole valve.
Hydraulic Wing, Master and Downhole Valves.
System Design includes:
Air or Natural Gas Supply – 100 to 200 PSIG
Standard or H2S-CO2 (NACE) Service
Hydraulic Outputs – 1,000 to 10,000 PSIG Subsurface Safety Valve and Surface Safety Valves
NOTE: Hydraulic regulator is provided on panels with Hydraulic Operated Surface Safety Valves
Pneumatic Outputs
ESD Loop – 50 PSIG
Surface Safety Valves – 100 to 200 PSIG
High/Low Pilot supply – 50 PSIG
Shutdown Outputs
Remote ESD or Local Shutdown
Fusible Plugs
High/Low Pilot Shutdown
Design includes Hydraulic Pump which can be operated
both Pneumatically or Manually
Atmospheric application – Desert or Marine
316 Stainless Steel Tubing and Fittings
Well Opening Sequence –
First – Hydraulic Operated Subsurface Safety Valve
Second – Master Surface Safety Valve
Third – Wing Surface Safety Valve
Well Closing Sequence –
First – Wing Surface Safety Valve
Second – Master Surface Safety Valve
Third – Hydraulic Operated Subsurface Safety Valve
|
|
|
|
|
|
|
 |
|
T.I.C. can meet any specific codes required for client
contracts, included are UL, BASEEFA, CON ELECM, AND CE,
ANSI-RAB/QMS ACCREDITED, MGMT.SYS, UKAS QUALITY MANAGEMENT, Etc.
|
|
|